SpecificationWarranty: 90 days from price paid Provide typical board image and motherboard label mannequin number when purchasingquantity: 1 How to ascertain a showering machine malfunction 1. Common faults of water ingress What is the fault of being unable to wash clothing due to continual water ingress after startup? The water level change is damaged, or the explanation for the leakage of the water level replace skin tube. Solution: Replace the water point swap and seal either ends of the rubber tube with glue. If the problem persists, replace the computer board. What is the fault of water ingress with out pressing the start button when turning at the power? The water inlet valve is broken, inflicting the pc board to burn out. Solution: It is critical to switch either the inlet valve and the computer board to solve the problem, yet changing the computer board by myself will still burn out. How to resolve regular washing faults 1. Turn on with out starting; What is the malfunction of washing clothing whereas rotating or no longer rotating after water ingress? The laptop board is burnt out, the motor is regionally brief circuited or burnt out, and the electrical calories is usually damaged. Solution: Measure the resistance price of the motor. If the resistance value is usual and the capacitance is normal, replace the pc board to unravel the problem. If not, replace the computer board and motor. 2. What is the malfunction when the showering program drains water whereas the water is normal? This fault needs to be due to washer with hand scrubbing function, and the drainage pullers are all 3 wire, which is attributable to the quick distance between the drainage puller and the drainage valve plug cable. Solution: Adjust the screw of the take hold of handle to make the gap somewhat longer, or change the single stroke (connect the tractor on each side and produce to an end the hand rubbing function line of the pc board to solve the problem. There isn't any should replace the computer board) How to solve dehydration faults 1. Other programs are normal, but they can not be dehydrated. When the drainage is done or starts, an alarm will sound and the fault code may be displayed. What is the fault code? The door change is broken, and the cylinder stability change is broken. Solution: Short circuit the computer board door switch and cylinder stability change socket (find the corresponding socket at the laptop board, insert the plug digital at the laptop board, peel off the cord pores and pores and skin on the corresponding socket at the laptop computer board, and twist it together directly) .) Other purposes are standard and can't be dehydrated. After the drainage is completed, watch for 4 mins for the alarm to sound, or what is the fault when there isn't any alarm? Water point change malfunction, solution: Replace the water point switch. Notice •if the shopper cannot find a similar product, the shopper can ship us the product and model, and we will provide it for you. • After installation, if now not working, please contact us as soon as possible, and our engineers can help you resolve the problem. • at the time of delivery, please confirm the correctness and completeness of the goods. If the products are mistaken or damaged, please refuse to signal and get in touch with us. • one hundred pc new that means new product. • Warranty:3 months guarantee, alternative and warranty. The visitor shall pay for the transportation despatched back. Shipping • the default shipping is normal delivery. • while you would love various shipping methods, please touch us, Feedback • Customer satisfaction is very important for us. Please dont leave any impartial or damaging suggestions before touch us feedback is not the high-quality choice to solve any problem. We can work together to solve any dispute. • Your five movie star suggestions is our motivation, looking forward to nice feedback!Thank you very much!