Tu tagad redzi preces, kas tiek piegādātas uz United States. Lai redzētu preces, kas tiek piegādas uz citām valstīm, izvēlies atbilstošu piegādes reģionu.
3-liter tank: internal diameter 18cm, inside height 12 cm. 4-liter tank: internal diameter 20cm, internal top thirteen cm. 6-liter tank: internal diameter 22cm, internal top 16cm. 8-liter tank: inner diameter 24cm, inside peak 18 cm. The product contains a seal, pluggable hoses and connectors, and a number of units of spare sealing plug are sent. Among them, extreme temperature resistant silicone sealing plug can be used when the tank body is heated. Elastic silica gel hosepipe inner and outer diameter is 4x7mm, or 5x8mm. The tank body is made from food grade 304 stainless steel, which can be safely contacted with food. The lid is a transparent borosilicate arched glass cover. The lid and tank physique are warmth resistant and heat resistant, excessive destructive pressure (over-100kpa), and may be externally related with high-power business grade vacuum machine. Our vacuum electric pumpIt is appropriate for low-viscosity slow-drying colloidal foam removal. For example, it can be used for epoxy defoaming. If it's used for silica gel defoaming, the hardness is 20 degrees or less. After many operations, the air is pumped after which deflated, which has a definite effect. If it is used to take away bubbles from high-hardness and quick-drying silica gel, we recommend that you just buy a machine with a high power of vacuum mechanical device and a detrimental strain of at least-95Kpa, or a suction of at the very least 2 liters in step with second. The small electrical suction pump geared up in our shop makes use of the input 110~220V AC, the output 12V DC 2 ~ 3A, the unfavourable strain is about-80 ~ Kpa, and the actual obtainable unfavorable stress is about-60 ~ Kpa.Another suction vacuum pump in our shop makes use of 220V AC, unfavourable stress is about-80 ~ Kpa, and the particular adverse pressure in the tank is about-70 ~ Kpa. There are other vacuum pumps in our shop from time to time. Welcome to buy. It is suggested that the air extraction time must be 1 to two minutes whenever for defoaming. After the air extraction, the decrease joint can be mechanically vacuum maintained and the joint would be pulled out at any time during the air extraction process. Items would be stored in vacuum for a long time for a number of days to a number of months. The vacuum preserving time mainly is dependent upon the vacuum destructive pressure in the tank and whether or not the contents are highly volatile. Lids and cans can be used as regular kitchenware,This allows you to preserve the worth of your funding and give away the lid manage from time to time. The above mannequin is small and economical electric pump, suitableThe 3-liter tank in our shop is used for pumping, electric pump of its personal unfavorable strain is-80Kpa, and the actual maximum destructive stress in the tank shows about-60kpa. This pump would not have a heat dissipation device. Generally, the pumping time is recommended to be 2 minutes. Long-time operation will overheat and Crash (generally get well after cooling), or make plastic elements deform, affecting product performance. The above is the pump modified by means of the outdated compressor, which is distributed randomly in assorted styles. The pump body is awfully prone to have rust and scratches, and it smells a little bit when running. It can be utilized for pumping and inflating. This pump is very heavy, about 4 ~ kg. The following electric pump is simple to operate (can solely pump),The adverse stress is about-80 ~ Kpa, and the particular damaging pressure within the tank is about-70 ~ Kpa,Electric pump beautiful workmanship, low noise and instant air extraction, with its personal switch and oil-water separator. 1. The following is a possible pumping scheme. Use straight forward room temperatureSealing plug and white suction interface, easy to function and short to pump, sealing plug could be straight put on the lid hole. 2. The following is the answer of extreme temperature resistant silica gel sealing plug, which is tightly installed and not clean to fall. The Blue sealing plug should be matched with the golf green suction connector. Reminder: 1) earlier than pumping, be certain that the rubber gasket is flat with the decrease plane of the glass cover. You can use your hands to flatten the rubber gasket along the outer outer edge of the glass cover. The photo above shows the impact picture of rubber gasket when the cover is seen in reverse. 2) when pumping, gently preserve the suction connector together with your hand for about a seconds, and the encircling of the lid could be pressed once or twice for speedy pressure. 3) vacuum meter can be immediately put into the barrel to immediately come across the adverse pressure value. After being accustomed to the destructive strain situation, you can not put vacuum meter. 4) Please handle the arched glass disguise gently during use. The conceal is pressure-resistant and shatter-resistant. 5) it can be deflated by means of touching sealing plug. Rapid deflating could lead on to colloid splashing in the tank. Vacuum meter eavesdrop on live away. 6) the effect could be effectively stepped forward after multiple pumping, and the pumping time is suggested to be 1 to two minutes each time, After energy failure, it is routinely sealed and stored in pressure, so there isn't any desire for continuous pumping. 7) simple variety small electrical pump cannot run for a long time, in any other case it might cause overheating and crash, or impact performance. 8) beginner users suggest using small cup to behavior a small quantity of experiments first. 9) please clear the tank and lid in time earlier than curing the glue. It is usually recommended to pad a chunk of paper on the bottom of the tank for simple cleansing of dirt.