We're showing you items that ship to United States. To see items that ship to a different country, change your delivery region.
Manual measurement, there could also be slight errors, for reference solely look of other batch labels will be slightly different, random delivery, customers who mind don't buy. Buying Guide:......................................................................................... Pre-sales guidanceQuestion 1: The compressor of the refrigerator keeps running, the refrigerator freezes normally, however the effect of the freezer is never goodThe left aspect of the again of the fridge is frozen and the freezing is choppy or there is not any cooling effect,Is it a thermostat problem?Answer 1: It&;s no longer a thermostat problem, it&;s generally a scarcity of refrigerant or an getting old compressorThe refrigerator has no longer been repaired, the fridge compressor has been runningQuestion 2: The fridge freezes normally, and the again of the fridge freezes evenly. Is it a difficulty with the thermostat?Answer 2: This is usually a problem with the thermostat, that are changed commonly 3: After replacing the compressor of the swimming tank or adding oxygen to the pipeline, the fridge doesn't stop, is it a controversy with the thermostat?Answer 3: Generally it isn't a thermostat problem, it is strongly recommended to use a fridge timer 4: The fridge compressor would not start, is it a difficulty with the thermostat?Answer 4: This is split into 3 situations:1: short-circuit the thermostat pin wiring. If it begins assuredly and the cooling is normal, update the thermostat. If the short-circuit compressor does not run cooling, it is a loss of refrigerant, now not a thermostat fault: In winter, the ambient temperature is awfully low, the fridge does not start, commonly the temperature compensation heating is broken or the thermostat is broken3: short-circuit thermostat compressor doesn't start, generally the line, compressor or starter failure.................................................................................. The again of the fridge compartment is frozen and lightly frozen. As shown in the determine blew, the compressor doesn't stop and fails. It is a problem with the temperature control circuit. The thermostat must be replaced........................................................................................ Refrigerator freezer freezes solely the left element has ice or the opposite side freezes, freezesUneven analysis, as proven within the decide blew, leads to the failure of the compressor now not shutting down isn't the challenge of the thermostatIt is a variety of disorders reminiscent of inside leakage and dealing pressure, piping and compressor problems.......................................................................................................... If your refrigerator thermostat is two feet, you can also purchase our 3 toes thermostat, which can be used instead, as lengthy since the size of the line is enoughH is hooked up to the brown wire, which is the stay twine of the ability supply;L is attached to the gray wire, which is the dwell wire of the lamp;C is attached to the white wire, which is the live twine of the compressor to the flexibility shipping terminal, C---connected to the compressor management terminal, L---connected to the temperature reimbursement control terminal two-leg temperature leadership only needs to be associated with the two feet of the three-leg temperature-controlled HC standard:1. Check whether or not the unique machine is WDF type or WPF kind (the two varieties are not common). The thermostat would not should be an analogous model, it's used on the same variety and same refrigeration equipmentcan be used in general. Check whether or not the appearance has similarities and whether or not the solving formulation is the same, otherwise it cannot be installed. Check whether the length of the probe is enough. The lengthy one is generally short, and the quick one is often now not long point to declare: the thermostat does not present unfastened trial, because the thermostat is mannequin new, and the trial after the trial will deliver bother to our secondary sales, and different shoppers are easily improper for second-hand. Please examine the fault and ensure that there aren't any different problems with the refrigerator earlier than putting an order prospects should preserve a reputable attitude. Maintenance is technical work, and it's not possible to save money. Hands-on means consider your own, we can help. But once you can&;t fix it, you assert that the equipment shouldn't good, and also you want a complete refund. There is not any free lunch in the world. People who don&;t want to endure any loss within the event that they can&;t fix it well, please watch out Middle Installation 3-Pins Refrigerator Freezer Temperature Controller ThermostatThe appearance of different batch labels might be slightly different, random delivery, customers who mind don't buy.